● Verify the input power supply is present and above all is correct. |
|
If a too elevated load is introduced, the power supply goes in “protection state”, lowering its nominal output voltaget, and accordingly RMT goes in alarm state. So, be sure to use a load suitable to the capacity of the power supply. Verify that the inrush current of the load is not excessive. . |
3. Giving power to the power supply without load and then giving a load, all is ok. But powering on the power supply with the load already connected, the power supply turns on and off repeatedly |
It’s a typical problem of undersized power source: be sure to use a suitable power supply (20% more at least than the nominal power of the power supply). |
|
The internal fan is supervised by the FCD device (Fan Control Device). |
|
● The CS connection (Current Sharing) must be wired between 2 or more power supplies in parallel each other, to ensure an equally sharing of the load current (increasing the reliability of the system. |
|
It is not always possible to put different series of power supplies in parallel. For example electrically: |